The Fuelchief SuperVault® has been shortlisted for Environmental Performance at the Global Tank Storage Awards 2020
Industries across the world need to ensure they are compliant when it comes to storing hazardous liquids such as petrol, diesel or chemicals. Fuelchief take the hassle out of this by engineering a compliant customised fuel tank called the SuperVault®. This engineered fuel tank is 4-hour fire-rated and is recommended due to its fire protective safety for commercial sectors. The SuperVault® tank offers elite fire-rated, bullet-proof, impact-resistant technology and has been designed, fabricated and tested in accordance with SwRI 95-03 which makes it the safest and most durable tank in the world. In many circumstances where diesel or petrol needs to be stored in commercial buildings, the SuperVault® is the only permitted tank. The SuperVault’s has been engineered to withstand conditions – from the sub-zero temperature of the Arctic to the blistering heat of the desert. No other fuel storage system in the world can provide a higher level of certified fire protection, insulation, and fuel security than a Fuelchief SuperVault®.
Multi-Hazard Approved
Around the world, new codes of practice and legislation often require all fire tanks to be either SwRI 95-03 or UL 2085 (2 hour) approved; the SuperVault® is both. It is the only 4-hour fireproof petrol tank certified for above ground petrol tanks, according to the Southwest Research Institute (SwRI) (Texas, USA) 95 – 03 multi-hazard test.
During this test, despite being subjected to fire, hose steam, projectiles and heavy-vehicle impact; the integrity of the SuperVault’s primary tank remained intact. This tank is also a popular choice for solvents, which often has the same “flashpoint” as petrol.
IMPORTANT NOTE: Insist on 95-03 as it is the only fire-rated tank in the world that can be repaired and re-used after the fire or event has occurred. The 95-03, 4-hour fire test involves an additional 2-hour fire exposure test using the same, fully assembled test tank for all tests.
In the event of a fire, the integrity of any tank certified to UL-2085 (2 hour) or SWRI 93-01 (4 hour) will be deemed to have been compromised and will not be compliant after the event.
True Secondary Containment
No additional bunding is required for the SuperVault®. Engineered and constructed for maximum protection, the SuperVault’s outer steel tank provides secondary containment as well as protecting the inner tank from the elements of nature and fire. The secondary containment tank also conforms to international requirements and is both pressure and vacuum testable on site.
Multipurpose Insulation
The interstitial insulation provides maximum thermal protection to the internal steel tank. This insulation material reduces heat transfer from the outer tank to the inner tank, therefore minimising the risk of an environmental disaster or the event of a pool fire. The porous nature of the insulating material allows for monitoring of leakage from the primary tank. In hot climates, the insulation also minimises fuel losses due to evaporation. The SuperVault® emergency vent controls the pressure in the tank in extreme fire conditions to eliminate explosion.
Long-lasting Warranty
A 30-year warranty is offered, providing the fuel tank is installed and maintained in accordance with the industry standards, including de-watering of the primary tank.
Below are the models and details for the SuperVault iTank range.
Sorry, the SuperVault iTank (SViT) Series – 13,000L – 88,900L is not available in your country.
The SuperVault iTank has been re-designed and certified as a rectangular ‘obround’ shape to cater for much tighter space requirements inside buildings resulting in the design of these rooms being much simpler, more cost effective and future-proof without the need to fire-rate the room.
The SuperVault iTank can be legally placed closer to buildings and public/protected places; negating the requirement to build a fire rated room around the tank, saving construction time and cost; ease of installation and relocation.
This precision engineered fuel tank is 4-hour fire-rated and is recommended due to its multi-hazard certification for commercial sectors. The SuperVault tank offers elite fire-rated, bullet-proof, impact-resistant technology which makes it the safest and most durable tank in the world and can take the weight of the heaviest of generators.
What is so important about SwRI 95-03? Find out in the video below.
When you’re buying fire-rated tanks/ tanks that need to go into buildings or intense climates, insist on SwRI 95-03 certified…
In our industry it is well known that an engine needs fuel to operate, and clean fuel at that. Just…
The space requirements and emergency power systems needed in all commercial buildings does not rank particularly high on the top…
Storage tank fabricating standards, fire codes, maintenance requirements are all intended to protect people and property from the inherent risks…
After a custom solution for your business? Chat to the team today.
We can help with your project
* Critical environmental benefits long-term
* Simplicity of specifying, installing and complying
* Most reliable investment in continuous power